Highlights & Features
|
- Universal 3x320-600VAC or 450-800VDC Input voltage
- Active PFC, PF up to 0.95
- Operating ambient temperature range: -40℃ to +85℃ (60 ℃ full load)
- Standard DIN-Rail mounting
- High efficiency, high reliability
- LED indicator for output status
- 150% peak power lasts for 3s
- Input under-voltage protection, output short circuit, over-current, over-voltage, over-temperature protection
- Support parallel use (2+1 current sharing) and series application
- DC OK, against backflow voltage
- Double-sided conformal coating, salt-spray proof
- Operating altitude up to 5000m
- OVC III (design refer to EN61010)
- Safety according to ANSI/ISA 71.04-2013 G3
- Design refer to UL/EN/IEC/BS EN62368, UL/EN61010, UL508
|
- Universal 3x320-600VAC or 450-800VDC Input voltage
- Active PFC, PF>0.95
- Operating ambient temperature range: -30℃ to +70℃, 60℃ @ 100% load without derating
- Standard DIN-Rail mounting
- High efficiency, high reliability
- LED indicator for output status
- 150% peak power lasts for 4.5s
- Output short circuit, over-current, over-voltage, over-temperature protection
- Supporting parallel (2+1 current sharing) and series application
- Fault alarm function, DC OK, against backflow voltage
- Double-sided conformal coating, salt-spray proof
- 485 Communication, remote shutdown (PS ON)
- Operating altitude up to 5000m
- OVC Ⅲ (Safety according to EN61010)
- 3 years warranty
- Safety according to ANSI/ISA 71.04-2013 G3
- Safety according to IEC/UL62368, EN61010, UL5
|
- Universal 3x320-550VAC or 450-800VDC Input voltage
three-phase input (two or three phase are available)
- Input withstand 3x600VAC/5s
- Active PFC, PF up to 0.95
- Operating ambient temperature range: -40℃ to +70℃
(50℃ full load)
- Standard DIN-Rail mounting
- High efficiency, high reliability
- LED indicator for output status
- 150% peak power lasts for 3s
- Output short circuit, over-current, over-voltage, over-temperature protection
- DC OK function
- Double-sided conformal coating
- Operating altitude up to 5000m
- OVC III, 2000m altitude (design refer to EN61010)
- Design refer to UL508, UL61010, UL/IEC62368
|
- Universal 3x320-600VAC or 450-800VDC Input voltage
- Active PFC, PF up to 0.94
- Operating ambient temperature range: -30℃ to
- +70℃, 60 ℃ @ 100% load without
- Standard DIN-Rail mounting
- High efficiency, high reliability
- LED indicator for output status
- 150% peak power lasts for 4s
- Output short circuit, over-current, over-voltage, over-temperature protection
- Supporting parallel (2+1 current sharing) and series
- Fault alarm function, DC OK, constant current
- Double-sided conformal coating, salt-spray proof
- 485 Communication, remote shutdown (PS ON)
- Operating altitude up to 5000m
- OVC Ⅲ (Safety according to EN61010)
- 3 years warranty
- Safety according to ANSI/ISA 71.04-2013 G3
- Safety according to IEC/UL/EN62368, IEC/EN61000, UL/EN61010, CISPR32/EN55032, UL508
|